ABB 2Line Manual page 83

Table of Contents

Advertisement

GENERALITA D’INSTALLAZIONE: CABLAGGIO - OVERVIEW OF THE INSTALLATION: WIRING
CITOFONO. COMPLESSI RESIDENZIALI DA 1 A 4 EDIFICI.
DOOR ENTRY SYSTEM. COMPOUND OF 1 TO 4 BUILDINGS
Potrà essere necessario l’aggiunta di elementi aggiuntivi per via delle distanze, numero di edifici, numero di dispositivi o cavi differenti
da quelli mostrati nelle tabelle (es. Rigeneratore di tensione BUS, amplificatore di segnale, ecc.). Consultare il produttore.
For distances, number of buildings, devices, or types of cable different from those shown in the tables, additional elements may be
necessary (e.g. BUS voltage regenerators, signal amplifiers, etc.). Consult the manufacturer.
A
B1B2 B1B2 B1B2 B1B2 B1B2
230 V
B1B2 B2 B3
B
LEGENDA - KEY
Distanza fra posto esterno e monitor più lontano
A
Distance between panel and telephone farthest away
Distanza fra posto esterno e interfaccia alimentatore
B
Distance between panel and power supply interface
Distanza fra interfaccia alimentatore
e monitor più lontano
C
Distance between power supply interface
and telephone farthest away
Distanza fra derivatore e citofono
D
Distance between tap-off and telephone
Distanza fra apriporta
e alimentatore apriporta
E
Distance between electric lock
and electric lock power supply
END
B2 B1
B1B2 B1B2 B1B2 B1B2 B1B2 B1B2
B1B2 B1B2 B1B2 B1B2 B1B2 B1B2
230 V
B1B2 B2 B3
EDIFICIO
BUILDING
ACCESSO ESTERNO
EXTERNAL POINT OF ENTRY
D
C
Tipo di cavo, numero di monitor nell'edificio e distanze massime
Type of cable, number of telephones in the building and maximum distances
2CSV4016AC
2CSV1068AC
2
1 mm
B
AWG: 17
CAT 5E
A: 275m
A: 220m
B: 240m
B: 45m
8
C: 275m
C: 220m
D: 25m
D: 25m
A: 250m
A: 200m
B: 240m
B: 45m
16
C: 250m
C: 130m
D: 25m
D: 25m
A: 225m
A: 180m
B: 225m
B: 45m
24
C: 225m
C: 85m
D: 25m
D: 25m
A: 200m
A: 160m
B: 200m
B: 45m
32
C: 200m
C: 60m
D: 25m
D: 25m
A: 175m
A: 140m
B: 175m
B: 45m
40
C: 175m
C: 50m
D: 25m
D: 25m
A: 150m
A: 120m
B: 150m
B: 45m
48
C: 150m
C: 40m
D: 25m
D: 25m
APRIPORTA - ELECTRIC LOCK
(1) Max. 12 Vac, 1.5 A
2CSV1037AC
(1)
TIPO DI CAVO
CABLE TYPE
TIPO DI CAVO - CABLE TYPE
2CSV1052AC
2CSV1067AC
2
UTP
1 mm
0.5mm
AWG: 20
AWG: 17
A: 120m
A: 120m
B: 120m
B: 120m
C: 120m
C: 120m
D: 25m
D: 25m
A: 110m
A: 125m
B: 110m
B: 125m
C: 110m
C: 125m
D: 25m
D: 25m
A: 110m
A: 100m
B: 110m
B: 100m
C: 110m
C: 100m
D: 25m
D: 25m
A: 100m
A: 85m
B: 100m
B: 85m
C: 100m
C: 85m
D: 25m
D: 25m
A: 75m
A: 85m
B: 75m
B: 85m
C: 75m
C: 85m
D: 25m
D: 25m
A: 75m
A: 65m
B: 75m
B: 65m
C: 75m
C: 65m
D: 25m
D: 25m
2CSV1008AC
E
2
2
1mm
0.5mm
E: 50m
E: 25m
2CSV1050AC
2
2
0.25mm
AWG: 22
A: 120m
B: 60m
C: 120m
D: 25m
A: 110m
B: 60m
C: 110m
D: 25m
A: 100m
B: 60m
C: 100m
D: 25m
A: 85m
B: 60m
C: 70m
D: 25m
A: 75m
B: 60m
C: 50m
D: 25m
A: 65m
B: 60m
C: 50m
D: 25m
230 V
230 V
V
2
0.25mm
E: 10m
81 | ABB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents