Motorola KEY 3000 User Manual page 264

Key variable loader
Table of Contents

Advertisement

Operational Error Messages
Operational
Error Message
Probable Cause(s):
ALGO IS NOT
SUPPORTED IN
TARGET!
Remedy(s):
Probable Cause(s):
Remedy(s):
BAD RESPONSE
FROM THE
KMF! XXXX
Probable Cause(s):
CONNECTED
TARGET DOES
NOT MATCH THE
ONE YOU
Remedy(s):
SELECTED!
Probable Cause(s):
INVALID
RESPONSE
Remedy(s):
FROM TARGET!
ASTRO 25 Operation
Chapter 9 Troubleshooting
Probable Cause and Remedy
1) You have attempted to load a
key with an algorithm type that is not
supported by the target.
2) You have attempted to load a
Key Group and one or more of the
keys in the group has an algorithm
type not supported by the target.
3) You have attempted to load ALL
Keys and one or more of the keys
has an algorithm type not supported
by the target.
1, 2, and 3) You cannot load keys
with algorithm types not supported
by target.
1) KMF is not set up correctly.
1) Request that KMF operator
verify that KMF is set up correctly. If
so, report the 4 digit code at the end
of the error message (xxxx) to Moto
rola Service Center.
1) You have attempted to perform
a Store and Forward keyload on a
target but have selected the wrong
target in LIST menu.
1) Select the correct target in LIST
menu.
1) Target is not ASTRO 25 compat
ible or not in ASTRO 25 mode.
1) Verify that target is ASTRO 25
compatible and in ASTRO 25 mode.