The server analyzes the diskette, searching for the latest ROM image. If the
diskette is not in place, the system continues to beep until a valid ROMPaq
diskette is inserted.
NOTE: If your server has an IMD, it displays the
diskette
this message as long as the server stops beeping, indicating that the diskette is a valid
ROMPaq diskette.
The ROMPaq diskette then flashes the system ROM.
If your server has an IMD, the IMD displays the following message:
ROMPaq flashing system ROM
At the successful completion of this process, a sequence of ascending audible
beeps is generated, and the IMD displays:
ROMPaq flash successful - Cycle Power
Or, if the flash is not successful, a descending sequence of audible beeps is
generated, and the IMD displays:
ROMPaq flash failed
5. After successful completion of this process:
a. Power down the server.
b. Remove the ROMPaq diskette.
c. Reset configuration switches.
d. Power up the server as usual.
-Or-
After a failed ROMPaq upgrade procedure, power down the server and repeat the
above process.
IMPORTANT: If you are performing this procedure on a server with redundant ROM
where both ROM images have been corrupted, repeat the process in succession (once for
each corrupted image). If only one image is corrupted, read the "Redundant ROM Image
Recovery" section for complete instructions.
HP Servers Troubleshooting Guide
message even after a valid ROMPaq diskette has been installed. Disregard
Please insert ROMPaq
Error Recovery
5-3