Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
SCSI port X, Drive ID Y has
exceeded the following
threshold(s)
SCSI port X, Drive ID Y is not
stamped for monitoring
SCSI port X, Drive ID Y may
have a loose connection
SOLUTION: Turn the system
off and attempt to reattach any
loose connections. If this does
not work, replace the cable(s)
and connection(s).
SCSI port X, Drive ID Y RIS
copies within this drive do not
match
HP Servers Troubleshooting Guide
Description
The monitor and performance
threshold for this drive has
been violated.
The drive has not been
stamped with monitor and
performance features.
SMART is unable to
communicate with the drive,
because the cable is not
securely connected, or the
drive cage connection has
failed.
The copies of RIS on the drive
do not match.
ADU Error Messages
continued
Recommended Action
Check and resolve the
threshold that has been
violated.
To change without destroying
the current configuration:
1.
Run ACU.
2.
Change the array
accelerator size and save
the configuration.
3.
Change the array
accelerator back to the
original size and save
again.
This should cause ACU to
stamp the drive with
monitoring and performance
features.
1.
Power down the system.
2.
Reconnect the cable
securely.
3.
Restart the system.
4.
If this does not solve the
problem, replace the
cables and connectors as
needed.
Check for other errors. The
drive may need to be replaced.
continued