Diskette Drive Test Error Codes - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Test Error Codes
Table B-6: Graphics Controller Unit Test Error Codes
Error Code
Description
514-XX
Graphics white screen test
failed
516-XX
Graphics noise pattern
test failed

600-699, Diskette Drive Test Error Codes

The 600 series of diagnostic error codes identifies failures with diskette, diskette
drive, or system board functions. Corrective action may require replacement of the
diskette, the diskette drive, or the system board assembly.
Table B-7: Diskette Drive Test Error Codes
Error Code
Description
600-XX
Diskette ID drive types test
failed
601-XX
Diskette format failed
602-XX
Diskette read test failed
603-XX
Diskette
write/read/compute test
failed
604-XX
Diskette random seek test
failed
605-XX
Diskette ID media failed
606-XX
Diskette speed test failed
607-XX
Diskette wrap test failed
608-XX
Diskette write protect test
failed
B-8
continued
Recommended Action
Recommended Action
The following steps apply to error codes 600-XX
through 610-XX:
1.
Replace the diskette and retest.
2.
Check the diskette power and signal cables and
retest.
3.
Replace the diskette power and signal cables
and retest.
4.
Replace the diskette drive and retest.
5.
Replace the system board and retest.
HP Servers Troubleshooting Guide
continued