Table C-3: 100 Series POST Error Messages
Error Code
171-2-IRC
Configuration Invalid
172-1-Configuration
NVRAM invalid
172-Configuration
Non-volatile Memory
Invalid
172-Default System
Configuration
Installed! Run System
Configuration Utility to
View/Modify Settings
172-1-Configuration
Non-volatile Memory
Invalid
172-System
Configuration
Nonvolatile Memory
Invalid. Initialization
Aborted.
173-PCI Config Slot
Mismatch
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
One or more of the
following messages may
also be displayed:
Comport Invalid
PCI Comport
Invalid
Incorrect IRQ
Video
Controller Must
be on Primary
PCI Bus
None
Nonvolatile configuration
corrupted or jumper
installed.
None
Nonvolatile configuration
corrupted.
None
Nonvolatile configuration
corrupted. The default
system configuration has
been installed.
None
Nonvolatile configuration
corrupted.
None
Battery is low or not
working.
None
Board replaced,
configuration not
updated.
continued
Action
Run the server setup utility
and correct.
Run the server setup utility
and correct.
Run the server setup utility
and correct.
Run the server setup utility to
make any changes to the
default configuration.
Run the server setup utility
and correct.
Turn off the server, replace
the battery located on the
sideplane board, and then
reboot the system. The
default nonvolatile
configuration will be loaded.
Run the server setup utility
and correct.
POST Error Messages
continued
C-11