Attended Recovery; Hardware Requirements - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Error Recovery

Attended Recovery

For attended recovery, ASR-2 executes the following functions:
NOTE: This feature is only available on servers that use the System Configuration Utility.
Attended recovery is not available on systems that use RBSU.
Logs the error information to the IML
Resets the server
Initiates Diagnostics from the hard drive
Enables remote access:
— If you have configured for dial-in access and have a modem with an
auto-answer feature installed, you can dial in and remotely diagnose or
reconfigure the server.
— If you have configured the Diagnostics for network access, you can access
the utilities over the network. Use Insight Manager for either dial-in or
network access.

Hardware Requirements

To obtain full utilization of ASR-2 over a modem, you need the following:
A non-PCI Hayes-compatible modem
Diagnostics installed on the system partition of the hard drive
ASR-2 configured to load Diagnostics after restart
You can also run Diagnostics remotely over an Internetwork Packet Exchange (IPX)
or Internet Protocol (IP) network using the Network feature.
To use Diagnostics on an IPX network, you must have Insight Manager 2.0 or
later, or a Novell Virtual Terminal (NVT) terminal emulator with VT100 or
American National Standards Institute (ANSI) terminal capabilities.
To use Diagnostics on an IP network, you must have Insight Manager 2.10 or
later, or a Telnet terminal emulator with VT100 or ANSI capabilities.