Series Post Error Messages - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages

800 Series POST Error Messages

Table C-9: 800 Series POST Error Messages
Error Code
800-Server Feature
Board must be
installed in slot 1 for
proper operation
801-Server Feature
Board is not properly
cabled to the system.
Verify that the server
management
information cable from
the system board to
the Server Feature
Board in slot 1 is
intact and fully
secured at both ends
C-30
Audible
Probable Source of
Beeps
Problem
None
The system has detected
the absence of the
Server Feature Board.
The Server Feature
Board is not installed in
the proper slot.
The Server Feature
Board does not match
this system.
None
The system has detected
that the server-
management information
cable is not properly
installed.
Action
1.
Install the Server Feature
Board in PCI slot 1.
2.
Reseat the Server
Feature Board.
3.
Be sure that the Server
Feature Board is from
this system.
1.
Be sure that a server-
management information
cable is installed in the
system.
2.
Inspect the server-
management information
cable for signs of
damage.
3.
Reseat the server-
management information
cable on the system
board and on the Server
Feature Board.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading