Table D-1: Array Diagnostic Utility (ADU) Error Messages
Message
Storage enclosure on SCSI
bus X indicated that the fan is
degraded.
SOLUTION: this condition
usually occurs on enclosures
with multiple fans and one of
those fans has failed. Replace
any fans not operating
properly.
Storage enclosure on SCSI
bus X indicated that the fan
module is unplugged.
SOLUTION: Make sure the fan
module is properly connected.
Storage enclosure on SCSI
bus X – Wide SCSI transfer
failed.
SOLUTION: This may indicate
a bad SCSI cable on bus X.
Try replacing the cable.
Swapped cables or
Configuration error detected. A
configured array of drives was
moved from another controller
that supported more drives
than this controller supports.
SOLUTION: Upgrade the
firmware on this controller. If
this doesn't solve the problem,
then power down system and
move the drives back to the
original controller.
HP Servers Troubleshooting Guide
Description
One or more fans in the
external storage unit have
failed.
A fan in the external storage
unit is not connected properly.
A cable on bus X has failed.
You have exceeded the
maximum number of drives
supported for this controller,
and the connected controller
was not part of the original
array configuration.
ADU Error Messages
continued
Recommended Action
Replace the failed fans.
Check and reseat all fan
connections securely.
1.
Replace the failed cable.
2.
If that does not solve the
problem, contact your
authorized service
provider.
1.
Upgrade the firmware on
this controller.
2.
If the problem is not
resolved:
Replace this controller
with the original controller.
-Or-
Replace this controller
with a new controller that
supports the number of
drives in the array.
continued
D-19