Graphics Controller Unit Test Error Codes - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

500-599, Graphics Controller Unit Test Error Codes

The 500 series of diagnostic error codes identifies failures with graphics or system
board functions. Corrective action may require replacement of the graphics board or
the system board assembly.
Table B-6: Graphics Controller Unit Test Error Codes
Error Code
Description
501-XX
Graphics controller test
failed
502-XX
Graphics memory test
failed
503-XX
Graphics attribute test
failed
504-XX
Graphics character set
test failed
505-XX
Graphics 80 x 25 mode
9 x 14 character cell test
failed
506-XX
Graphics 80 x 25 mode
8 x 8 character cell test
failed
507-XX
Graphics 40 x 25 mode
test failed
508-XX
Graphics 320 x 200 mode
color set 0 test failed
509-XX
Graphics 320 x 200 mode
color set 1 test failed
510-XX
Graphics 640 x 200 mode
test failed
511-XX
Graphics screen memory
page test failed
512-XX
Graphics gray scale test
failed
HP Servers Troubleshooting Guide
Recommended Action
The following steps apply to error codes 501-XX
through 516-XX:
1.
Replace the monitor and retest.
2.
Replace the graphics controller and retest.
- Or -
If the controller is on a separate board, replace
the graphics controller and retest.
3.
Replace the system board and retest.
Test Error Codes
continued
B-7

Advertisement

Table of Contents
loading