1100-1199, Serial Test Error Codes; Serial Test Error Codes - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table B-7: Diskette Drive Test Error Codes
Error Code
Description
609-XX
Diskette reset controller
test failed
610-XX
Diskette change line test
failed
699-XX
Diskette drive/media ID
error

1100-1199, Serial Test Error Codes

The 1100 series of diagnostic error codes identifies failures with serial interface
board or system board functions. Corrective action may require replacement of the
serial/parallel interface board or the system board assembly.
Table B-8: Serial Test Error Codes
Error Code
Description
1101-XX
Serial port test failed
1109-XX
Clock register test failed
HP Servers Troubleshooting Guide
continued
Recommended Action
1.
Replace the media and retest.
2.
Run the server setup utility and retest.
Recommended Action
The following steps apply to error codes 1101-XX and
1109-XX:
1.
Check the switch settings on the serial/parallel
interface board (if applicable) and retest.
2.
Replace the serial/parallel interface board (if
applicable) and retest.
3.
Replace the system board and retest.