POST Error Messages
Table C-2: Non-Numeric Error Messages or Beeps Only
Error Code
Power Fault Detected
in Hot-Plug PCI Slot X
Processor in incorrect
socket. - System
Halted!.
Processor packages
do not match..
Please make sure
that all processor
packages are the
same.
- System Halted!
REDUNDANT ROM
ERROR: Backup
ROM invalid. - run
ROMPAQ to correct
error condition.
REDUNDANT ROM
ERROR: Bootblock
invalid. - contact
COMPAQ
Representative.
RESUME – F1 key
(Run System
Configuration Utility –
F10 key)
Unsupported
Processor Detected
System Halted.
C-6
Audible
Probable Source of
Beeps
Problem
2 short
PCI-X Hot Plug
expansion slot was not
powered up properly.
None
Processor is installed in
socket 2 only.
1 long,
Installed processors are
1 short
different types.
None
System ROM and
redundant ROM are both
corrupt.
None
ROM bootblock is
corrupt.
None
As indicated to continue.
None
A configuration error
occurred during POST.
1 long, 1
Processor not supported
short
by current system ROM.
continued
Action
Reboot the server.
Install processor in socket 1.
Install processors of the same
type.
Run ROMPaq Utility.
Contact authorized service
provider.
Press the F1 key.
Press the F10 key to run
server setup utility.
Check documentation for
supported processors. If
supported, remove the
processor and update system
to latest ROM.
HP Servers Troubleshooting Guide
continued