HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 222

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-12: 1600 Series POST Error Messages
Error Code
1611-Slot Fan Failure
Detected
1611-System Fan
failure detected
1611-System Fan not
present
1612-Primary power
supply failure.
1613-Low System
Battery.
1614- Redundant Fan
Failure
1615-Power Supply
Configuration Error
C-42
Audible
Probable Source of
Beeps
Problem
None
Required fan not
spinning.
None
Required fan not
spinning.
None
Required fan not
installed.
2 short
Primary power supply
has failed.
None
Real-time clock system
battery is running low on
power.
None
Fan is not spinning.
None
Your configuration
requires an additional
power supply. A moving
bar is displayed,
indicating that the system
is waiting for another
power supply to be
installed.
continued
Action
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
Replace power supply as
soon as possible.
Replace battery (or add
external battery) as soon as
possible.
1.
Check fans.
2.
Reseat fan cable.
3.
If this does not solve the
problem, replace the fan.
Install the additional power
supply.
HP Servers Troubleshooting Guide
continued