Motorola WiNG 5.5 Reference Manual page 875

Table of Contents

Advertisement

10.Refer to the
Temperature Trend Over Last Day
across specific hours of the day. Use this information to help determine whether the AP8132 can be upgraded or powered
off during specific hours of the day.
11. Select the
Motion
tab.
Figure 13-93 Access Point - Environmental Sensor screen (Motion tab)
12.Refer to the
Motion
table to assess the sensor's detected movement within the AP8132's immediate deployment area.
Motion is measured in intervals. The table displays the
Motion (count per
interval). Compare these two items to determine whether the AP8132's deployment location remains
consistently occupied by client users. For more information on enabling the sensor, see
on page
5-171.
13.Refer to the
Motion Trend Over Last Hour
graph in combination with the Light and Temperature graphs (in particular) to assess the deployment area's activity level.
14.Refer to the
Motion Trend Over Last Day
specific hours of the day. Use this information to help determine whether the AP8132 can be upgraded or powered off
during specific hours of the day.
15. Select the
Humidity
tab.
graph to assess whether deployment area temperature is consistent
Current Motion (count per interval)
graph to assess the fluctuation in user movement over the last hour. Use this
graph to assess whether deployment area user movement is consistent across
Statistics 13 - 137
and a
20 Minute Average
Environmental Sensor Configuration