Configuring E2E Reliability - Huawei SmartAX MA5603T Configuration Manual

Access module
Hide thumbs Also See for SmartAX MA5603T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
l
----End

14.4.5.6 Configuring E2E Reliability

This topic describes how to configure end-to-end (E2E) protection schemes for the enterprise
private line service which has a high requirement on service reliability.
Context
Reliability covers equipment reliability, upstream networking protection, and downstream
networking protection. For details on reliability data planning, see
Reliability Data
l
l
NOTE
This topic describes how to configure five mainstream protection schemes. Select required protection schemes
based on the carrier's requirement and actual networking scenario.
Procedure
l
Issue 01 (2014-04-30)
Run the display clock mode command to query the working mode of the clock. Ensure
that the working mode of the clock daughter board is Tracing.
huawei(config)#display clock mode
Clock manage-mode:Third-mode
Clock subboard work-mode:Tracing
Configure the ONU-side clock.
1.
Configure the PON line clock as the system clock.
huawei(config)#clock source 0 0/0/1
huawei(config)#clock priority system 0
2.
Query the configuration and status of the system clock source.
Run the display clock source command to query the configuration and status of the
system clock source.
huawei(config-if-tdm-0/1)#quit
huawei(config)#display clock source
--------------------------------------------------------------------
Index
Type
Source
--------------------------------------------------------------------
0
line
0/0/1
1
--
-/ -/ -
2
--
-/ -/ -
3
--
-/ -/ -
4
--
-/ -/ -
5
--
-/ -/ -
6
--
-/ -/ -
7
--
-/ -/ -
8
--
-/ -/ -
9
--
-/ -/ -
--------------------------------------------------------------------
Plan.
Upstream networking protection includes link aggregation group and protection group.
Usually, link aggregation group is configured when the GIU board is used to transmit traffic
upstream; protection group is configured when the main control board is used to transmit
traffic upstream. The two protection schemes are not configured at the same time.
Downstream networking protection includes Type B, Type C single homing, and Type C
dual homing, which are used to protect service ports. Ports on the same ONU can be
configured only with the same protection scheme.
Configure a link aggregation group.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14 FTTM Configuration (Base Station Access)
State
Priority
Normal
0
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
QL
Selected
---
YES
NO
---
NO
---
NO
---
NO
---
NO
---
NO
---
NO
---
NO
---
NO
---
13.2.6 Principle of
1474

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartax ma5600tSmartax ma5608t