SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
3.
----End

13.3.6.9 Verifying Services

This topic describes how to use the PDH/SDH tester to verify the private line access service.
Prerequisites
The private line service has been configured.
Issue 01 (2014-04-30)
b.
Run the tx clock or port portid udt system command to configure the system clock
as the transmit clock of the port.
c.
Run the display port state command to query the transmit clock of the E1 port.
huawei(config)#interface tdm
huawei(config-if-tdm-)#port 0 udt system
huawei(config-if-tdm-)#display port state 0
---------------------------------------
Port
: 0
State
: normal
Mode
: UDT
Code
: HDB3
Looptype
: -
Timeslot
: -
Clock
: system
CRC4
: -
Signaling
: -
ESF
: -
Impedance
: 120 Ohm
---------------------------------------
Query configurations and the status of the system clock source.
Run the display clock source command to query configurations and the status of the system
clock source.
huawei(config-if-tdm-)#quit
huawei(config)#display clock source
---------------------------------------------------------------
Index
Config
Type
---------------------------------------------------------------
0
YES
line
1
NO
--
2
NO
--
3
NO
--
4
NO
--
5
NO
--
6
NO
--
7
NO
--
8
NO
--
9
NO
--
---------------------------------------------------------------
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13 FTTO Configuration (Large-sized Enterprise Access)
Source
State
0/0/1
Normal
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
-/ -/ -
---
Priority
Output
0
YES
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
1357