6.1

Programming with a Telephone Set

System programming can only be executed using the system's first extension slot (default
extension 11) with an analog extension (MF), a KS-type system telephone or an optiPoint 500
system telephone. Programming cannot be done simultaneously on two extensions.
The reason for initially using a system telephone at extension slot 11/101 is that the systems
are shipped from the factory with the following default settings:
A1 and B1 slots are assigned to C1 and D1 slots on the motherboard (see "Connecting
Extensions to the System's Internal MDF (Main Distribution Frame)" on page 4-38).
When using a system telephone with a display, you can follow the programming steps visually
on the display.
To access the Programming Mode on the specified extensions:
Programming Extension: *95 + PASSWORD (default: 31994).
Programming Mode Syntax
All the programming is done by entering a code then a setting.
Each additional setting entered is followed by a confirmation tone (1 beep). When the setting's
entry is incorrect, it is followed by 3 beeping tones after which the system returns to its initial
programming state.
There are three different ways to finalize the configuration of a setting and return
to the initial state of the Programming Mode:
Letting the entry of the setting complete automatically
Pressing the # key after entering the setting
Waiting 5 seconds after entering the setting.
If no code or setting is entered, the system will continue to wait for an entry or will assume that
a "null entry" occurred. It will proceed to the next programming step according to the code first
entered.
After a setting is programmed, the display will return to the initial state of the Programming
Mode. To exit Programming Mode simply replace the handset.
Issues Concerning Changes to the Default Password
Access to the system's Programming Mode is protected by password to prevent unauthorized
access.
To change the default password (31994) you must enter Programming Mode:
A31003-K1160-S100-03-7620
Service Manual
Programming with a Telephone Set