7.2

Comments about the System's Programming Codes

7.2.1

Important settings

Dialing Mode on an External Analog Line (119)
The system supports two dialing modes for external and absent lines (for unused external line
slots):
DP - Dial Pulse
MF - Multifrequency (Tone).
Default Access to a Group of External Lines (002)
This feature specifies dialing "0" as the dialing method for a group of external lines. The default
external line access code is "0."
If the user enters an external access code of "0," the system will search for a free
line in the group assigned. If there is no free line, the system will search for a line in
another group.
Analog Line Attendants (142)
These define the extensions or Consecutive Groups that will first answer calls received from a
specific external line during a specified time period (Day/Night). Any extension can also be
configured as a Second Attendant. In this case an extension only receives a call when the
external line answering extension does not answer the call within a specified time (Code 083).
When this occurs, extensions configured as Second Attendants for external lines receive the
call simultaneously with the First Attendants.
If an extension is connected to a Door Opener device, the device cannot be config-
ured as an Attendant.
Within a Subscriber Group an incoming call rings at the first extension available, ac-
cording to the call distribution plan configured for the UCD Subscriber Group.
When no first DID is configured, the call will be forwarded to the Overflow exten-
sion. In the event that no Overflow extension is configured, the call ends. In such
cases no extension is signaled, the call cannot be captured, and the
system will continue to wait until the carrier clears this external line and makes it
available.
A31003-K1160-S100-03-7620
Service Manual
Configuring the system specifically for the client
Comments about the System's Programming Codes
7-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1150Hipath 1120Hipath 1190