Acceptance test
7.3 Acceptance test with Startdrive
7.3.4

Completing the acceptance test with report

Description
The acceptance report can be created at any time, for example, even when individual tests
have not yet been performed or completed with faults. This allows the intermediate states
also to be documented.
The actual final acceptance report, however, makes sense only when all tests have been
performed successfully.
Requirement
● All tests have been successfully completed. The individual tests are all identified
positively with a green tick.
Creating an acceptance report
1. The overview under "Create report" lists all drives and their current test status.
2. In the "Completion" screen form, select the drives for which you would like to create the
report.
You can select any number of drives, regardless of their test status.
The drive instances to which the results were transferred are also displayed in the list as
drop-down sub-entries. These drive instances are always included in the acceptance
report with the selection of the respective main drive.
3. Click on the "Create" button.
The "Save as" dialog opens.
4. When you select a drive, its drive name is preset as a suggestion for the file name for the
acceptance test as standard.
When you select multiple drives, a dialog for selecting the directory for storing the report
opens. For each drive selected, a report is saved with the name of the drive.
Optional: Creating a function table
You can use the function table to create a user-defined overview that is documented in the
acceptance report in addition to the results of acceptance test.
The overview is structured as follows:
Column
Operating mode
Description
Protective device
Version
Axis
Monitoring
348
Explanation
Select one of the specified operating modes from the drop-down list to map the
desired scenario.
Enter an explanatory comment for the selected operating mode.
Select the protective mechanism to be used in the applicable scenario from the
drop-down list.
Enter an explanatory comment on the protective device being used.
Select the respective drive axis from the drop-down list.
Select the Safety Integrated Function being used from the drop-down list.