Maintenance

9.2 Note regarding firmware update

9.2
Note regarding firmware update
Firmware update without POWER ON and acceptance test
If the message A01007 "POWER ON required for DRIVE-CLiQ component" appears after a
firmware update, death or serious injury can be caused if a person enters the danger zone
of the motors.
• Then perform a partial acceptance test.
• Do not enter the danger zone of the motor until the acceptance test has been
Unwanted motion if components are replaced without a function test
After a component replacement, connections or functions can be defective so that death or
serious injury can result if a person enters the danger zone of the motors.
• Perform a POWER ON before resuming operation.
• After component replacement, always run a simplified function test.
374
WARNING
successfully completed.
WARNING
You can find more detailed information in the chapters "Test scope for specific
measures (Page 341)" and "Acceptance test with Startdrive (Page 344)".
Function Manual, 12/2018, 6SL3097-5AR00-0BP1
Safety Integrated