Commissioning

6.8 Commissioning: Basic procedure

6.8
Commissioning: Basic procedure
6.8.1

Making basic settings

6.8.1.1

Starting the safety commissioning

Requirement
For safety reasons, you can only set the safety-relevant parameters of the 1st channel offline
for Startdrive. To set the safety-relevant parameters of the 2nd channel, the drive must be
online. The settings are protected by a password.
Icon
Activating safety settings
1. Click the "Go online" icon.
2. Click the
The dialog for the password input opens.
3. Enter the password.
You only have to enter a new password at the first start to replace the default password.
4. Click "OK" to accept the settings.
The safety commissioning is activated.
6.8.1.2

Making basic safety settings

282
Description
Startdrive is not online.
Startdrive is online. The processing mode is not activated yet.
Startdrive is online. The processing mode is active. In addition to the safety mark-
ing, a "pin"
icon in the toolbar of the parameterization editor.
"Drive axis > Parameter > Safety Integrated > Function selection"