Configure Global Profile For Ecn - Lenovo RackSwitch G8264 Application Manual

For lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

3. Enable WRED for the port .
4. Enable a transmit queue.
5. Configure WRED thresholds (minimum, maximum, and drop rate) for TCP traffic.
6. Configure WRED thresholds (minimum, maximum, and drop rate) for non‐TCP 
traffic.

Configure Global Profile for ECN

1. Enable ECN globally.
2. Enable a transmit queue.
3. Configure ECN thresholds (minimum, maximum, and drop rate) for TCP traffic.
4. Select the port.
5. Enable ECN for the port.
© Copyright Lenovo 2016
RS G8264(config­if)# random­detect enable
RS G8264(config­if)# random­detect transmit­queue 0 enable
RS G8264(config­if)# random­detect transmit­queue 0 tcp min­threshold 11 
max­threshold 22 drop­rate 33
Note: Percentages are of Average Queue available in hardware and not 
percentages of traffic.
RS G8264(config­if)# random­detect transmit­queue 0 non­tcp min­threshold 
44 max­threshold 55 drop­rate 66
RS G8264(config­if)# exit
RS G8264(config)# qos random­detect ecn enable
RS G8264(config)# qos random­detect transmit­queue 0 enable
RS G8264(config)# qos random­detect transmit­queue 0 tcp min­threshold 1 
max­threshold 2 drop­rate 3
Note: Percentages are of Average Queue available in hardware and not 
percentages of traffic.
RS G8264(config)# interface port 1
RS G8264(config­if)# random­detect ecn enable
RS G8264(config­if)# exit
Chapter 13: Quality of Service