Setting the Management Interface Default IP Address
68
G8264 Application Guide for ENOS 8.4
To facilitate switch boot up, the in‐band and out‐of‐band management interfaces
are configured with factory default IP addresses. These are as follows:
VLAN 1/ Interface 1: 192.168.49.50/24
Out‐of‐band Management Port 1: 192.168.50.50/24
If you configure static IP addresses or if DHCP/BOOTP addresses are assigned to
these interfaces, the factory default IP addresses will not be applied. By default,
DHCP and BOOTP are enabled on the management interfaces.
If you add interface 1 to another VLAN and do not configure any IP address, the
factory default IP address will be automatically assigned to the interface.
We recommend that you disable the factory default IP address configuration after
the switch boot up and configuration is complete. Use the following command:
RS G8264(config)# no system default-ip [data|mgt]