1. Enable failover globally: 
2. Configure trigger 1 and add monitor and control ports: 
3. Enable failover trigger: 
© Copyright Lenovo 2016
G8264(config)# failover enable
G8264(config)# failover trigger 1 mmon monitor member 5
G8264(config)# failover trigger 1 mmon control member 8
G8264(config)# failover trigger 1 mmon control vmember 9.1,9.2,9.3,9.4
Note: If you try to add a physical port (that has vPorts configured) as a member of 
a trigger, you may see the following error message when you enable the trigger:
G8264(config)# failover trigger 1 ena
Failover Error: trigger 1 physical port 9 has virtual ports.
G8264(config)# failover trigger 1 enable
Chapter 25: Unified Fabric Port