Example 2: Trunk Mode
1. Configure port 1 as server port:
2. Turn on UFP.
3. Configure port 1 as UFP.
4. Configure virtual port.
5. Configure vPort trunk mode.
6. Configure vPort default VLAN.
7. Specify QoS parameters for the vPort.
8. Enable the vPort.
9. Configure port 2 as UFP.
10. Configure virtual port.
422
G8264 Application Guide for ENOS 8.4
Following is an example configuration of UFP vPorts in trunk mode.
G8264(config)# system serverports port 1
RS G8264(config)# ufp enable
G8264(config)# ufp port 1 enable
Warning: "Tagging/Trunkmode" is enabled on UFP port 1
G8264(config)# ufp port 1 vport 1
G8264(config_ufp_vport)# network mode trunk
G8264(config_ufp_vport)# network defaultvlan 100
G8264(config_ufp_vport)# qos bandwidth min 25 (in percentage)
G8264(config_ufp_vport)# qos bandwidth max 100 (in percentage)
G8264(config_ufp_vport)# enable
G8264(config_ufp_vport)# exit
G8264(config)# ufp port 2 enable
Warning: "Tagging/Trunkmode" is enabled on UFP port 2
G8264(config)# ufp port 2 vport 3