272
G8264 Application Guide for ENOS 8.4
Static ACL flow entries can be deleted using the command: 
RS G8264(config­openflow­instance)# static­table remove index <index number>
Static flow table information can be viewed using the following commands:  
In OpenFlow version 1.0:  
RS G8264(config­openflow­instance)# show openflow table
Openflow instance 1 is currently disabled
Openflow Instance Id: 2
BASIC FLOW TABLE
CONTROLLER ADDED FLOWS
Flow:1 
  Filter Based, priority:    0, hard­time­out:     0, idle­time­out:     0
  cookie: 0x0
  QUALIFIERS: 
  ACTION:  drop
  STATS:   packets=0, bytes=0 
Flow:2 
  Filter Based, priority:65535, hard­time­out:     0, idle­time­out:     0
  cookie: 0x0
  QUALIFIERS: ether­type:0x88cc
     protocol:  0, tos: 0
     src­ip:0.0.0.0/32, dst­ip:0.0.0.0/32
     src­port:    0, dst­port:    0
  ACTION:  output:CONTROLLER [Max Len: 65535 / ­  bytes (C/S)]
  STATS:   packets=0, bytes=0 
Flow:3 
  Filter Based, priority:    2, hard­time­out:     0, idle­time­out:     0
  cookie: 0x0
  QUALIFIERS: 
  ACTION:  output:CONTROLLER [Max Len: 65535 / ­  bytes (C/S)]
  STATS:   packets=0, bytes=0 