Ufp Configuration Examples; Example 1: Access Mode - Lenovo RackSwitch G8264 Application Manual

For lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

UFP Configuration Examples

Example 1: Access Mode

1. Configure port 1 as server port:
2. Turn on UFP. 
3. Configure port 1 as UFP. 
4. Configure virtual port. 
5. Configure vPort access mode. 
6. Configure vPort default VLAN. 
7. Specify QoS parameters for the vPort. 
8. Configure PVID/Native VLAN for port 2. 
© Copyright Lenovo 2016
Following is an example configuration of UFP vPorts in access mode. 
G8264(config)# system server­ports port 1
G8264(config)# ufp enable
G8264(config)# ufp port 1 enable
Warning: "Tagging/Trunk­mode" is enabled on UFP port 1
G8264(config)# ufp port 1 vport 1
G8264(config_ufp_vport)# network mode access
G8264(config_ufp_vport)# network default­vlan 100
G8264(config_ufp_vport)# qos bandwidth min 25                   (in 
percentage)
G8264(config_ufp_vport)# qos bandwidth max 100                  (in 
percentage)
G8264(config_ufp_vport)# enable
G8264(config_ufp_vport)# exit
G8264(config)# interface port 2
G8264(config­if)# switchport mode access
G8264(config­if)# switchport access vlan 100
Chapter 25: Unified Fabric Port