UFP Configuration Examples
Example 1: Access Mode
1. Configure port 1 as server port:
2. Turn on UFP.
3. Configure port 1 as UFP.
4. Configure virtual port.
5. Configure vPort access mode.
6. Configure vPort default VLAN.
7. Specify QoS parameters for the vPort.
8. Configure PVID/Native VLAN for port 2.
© Copyright Lenovo 2016
Following is an example configuration of UFP vPorts in access mode.
G8264(config)# system serverports port 1
G8264(config)# ufp enable
G8264(config)# ufp port 1 enable
Warning: "Tagging/Trunkmode" is enabled on UFP port 1
G8264(config)# ufp port 1 vport 1
G8264(config_ufp_vport)# network mode access
G8264(config_ufp_vport)# network defaultvlan 100
G8264(config_ufp_vport)# qos bandwidth min 25 (in
percentage)
G8264(config_ufp_vport)# qos bandwidth max 100 (in
percentage)
G8264(config_ufp_vport)# enable
G8264(config_ufp_vport)# exit
G8264(config)# interface port 2
G8264(configif)# switchport mode access
G8264(configif)# switchport access vlan 100
Chapter 25: Unified Fabric Port
421