9.10 Top cover ASSY
■ Touch panel models
9.10.1 Panel PCB ASSY
(1) Disconnect all flat cables from the panel PCB ASSY.
Panel flat cable
(2) Release the two hooks A, and remove the panel PCB ASSY from the panel FFC holder.
(3) Remove the taptite cup S M3x8 SR screw to disconnect the FG harness A.
(4) Release each flat cable and the FG harness A from the securing fixtures of panel FFC
holder.
(5) Release the hook B, slide the panel FFC holder in the direction of the arrow to release
each tab, and remove the panel FFC holder.
Panel PCB ASSY
Harness routing: Refer to
LCD flat cable
Hooks A
Tab
Hook B
"1. Left side of the machine (Touch panel
Panel PCB ASSY
Fig. 3-34
Panel FFC holder
FG harness A
Taptite cup S M3x8 SR
Fig. 3-35
3-51
KEY PCB flat cable
NFC flat cable
models)".