3. ERROR INDICATIONS

This machine includes a self-diagnosis function. If the machine does not work normally it
judges that an error has occurred, and indicates the corresponding error message on the
LCD, which in turn helps the service personnel to quickly find out the problem.
3.1 Error Codes
Errors in shaded column do not usually occur during normal use. The possible causes are
noise around the installation site, fluctuation of the power supply voltage, and failures in the
software.
Error
codes
0101
Communication error between the
0102
engine ASIC and motor driver or faulty
motor driver.
Cannot detect the synchronized signal
of the paper feed motor.
0201
The speed of the paper feed motor
does not stabilize within the specified
time.
0202
0203
Eject motor failure was detected.
Cannot detect the lock signal of the
0300
polygon motor for the laser unit
(second time).
Cannot detect the lock signal of the
0305
polygon motor for the laser unit (first
time).
Cannot detect the synchronized signal
0401
of the polygon motor for the laser unit
(second time).
0402
Cannot detect the synchronized signal
0405
of the polygon motor for the laser unit
(first time).
The center thermistor of the fuser unit
0501
has not reached the specified
temperature within the specified time.
The center thermistor of the fuser unit
has not reached the specified
0502
temperature within the specified time
after it was heated normally to the
certain level.
The center thermistor of the fuser unit
0503
detected a temperature higher than
the specified value.
Description
2-10
Refer
Error
to:
codes
After the heat unit was heated
normally, the center thermistor of the
0504
fuser unit detected a temperature
lower than the specified value.
The center thermistor of the fuser unit
detected a temperature rise greater
2-42
0505
than the specified value within the
specified time.
The center thermistor of the fuser unit
detected a temperature fall greater
2-42
0506
than the specified value within the
specified time.
The side thermistor of the fuser unit
0508
did not detect a temperature rise
when the heater was ON.
The hardware detected a temperature
2-42
050A
error through the center thermistor or
the side thermistor of the fuser unit.
When the center thermistor of the
fuser unit was lower than the idle
2-43
050B
temperature, the side thermistor
detected a temperature higher than
the specified temperature.
When the center thermistor of the
fuser unit was higher than the idle
2-43
050C
temperature, the side thermistor
detected a temperature lower than the
specified temperature.
2-43
050D ―
050F
An error occurred in the internal
2-43
0800
temperature sensor.
Detected irregular power supply for
2-44
0900
more than 100 times.
2-44
0A01
2-44
0A02
Detected a main fan failure.
Description
Confidential
Refer
to:
2-44
2-44
2-44
2-44
2-45
2-45
2-45
2-45
2-46
2-46

Hide quick links: