Configure For Country/Region And Model (Function Code: 74) - Brother HL-L5000D Service Manual

Hide thumbs Also See for HL-L5000D:
Table of Contents

Advertisement

1.3.17 Configure for country/region and model (function code: 74)

<Function>
This function is used to customize the machine according to language, function settings, and
worker switch settings.
<Operating Procedure>
Non touch panel models
(1) Press the [▲] or [▼] key in the initial
state of maintenance mode to display
"MAINTENANCE 74" on the LCD, and
press the [OK] key. The spec code
currently set is displayed on the LCD
(The first digit is flashing).
(2) Press the [▲] key to enter "1", or the
[▼] key to enter "0". Then press the
[OK] key. The second digit starts to
flash.
(3) Press the [▲] key to enter "1", or the
[▼] key to enter "0" similarly. Then
press the [OK] key. The second digit is
completed and the fourth digit starts to
flash.
(4) The third digit and fourth digit changes
at once when the [▲] or [▼] key is
pressed. Press the [Go] key when the
desired value is shown on the LCD.
The new setting is saved, and
"PARAMETER INIT" is displayed on
the LCD. The machine then returns to
the initial state of maintenance mode.
Touch panel models
(1) Press the [7], and then the [4] key in
the initial state of maintenance mode.
The spec code currently set is
displayed on the LCD.
(2) Enter the spec code (four digits) you
want to set.
(3) Press the [Mono] key to save the new
setting, and "PARAMETER INIT" is
displayed on the LCD. The machine
then returns to the initial state of
maintenance mode.
5-38