Siemens SINUMERIK 840Di Diagnostic Manual page 104

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
10257
[up to SW 3.x only] Channel %1 reorg sequence canceled
Parameters:
%1 = Channel number
Definitions:
Internal sequence error. REORG is not possible at present - program abort.
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Press RESET.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10258
[up to SW 3.x only] Mode group %2 channel %1: ID invalid or duplicated
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
An invalid channel/mode group assignment was detected on power-up.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check machine data ASSIGN_CHAN_TO_MODE_GROUP.
Program
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Continuation:
10259
[up to SW 3.x only] Channel %1
Parameters:
%1 = Channel number
Definitions:
REORG is not possible at present.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
--
Program
Switch control OFF - ON.
Continuation:
10260
[up to SW 3.x only] Channel %1
Parameters:
%1 = Channel number
Definitions:
REORG is not possible at present.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
--
Program
Switch control OFF - ON.
Continuation:
2-104
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links: