Error Codes of Alarm 300500
Extension 2
-
Explanation
The limits of the internal processor hardware stack or of software stack in the data mem-
ory have been violated. The cause is probably a hardware error on the control module.
Remedy
Reload drive software. Replace the control module.
Error code
0011H
Error text
NMI due to watchdog
Extension 1
Opcode address
-
Extension 2
Explanation
The watchdog on the control module has timed out. The cause is a hardware error in the
time base on the control module.
Remedy
Replace the control module.
Error code
0012H
Error text
NMI due to clock cycle failure
Extension 1
-
Extension 2
-
Explanation
The NC basic cycle, which is generated on the NC and transferred to the drive via the
drive bus cable, has failed.
Possible causes: NCK reset, EMC interference, NC hardware error, cable break on the
drive bus, hardware error on the control module.
Remedy
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the NC hardware, replace the control module.
Error code
0013H
Error text
Clock cycle came too early
Extension 1
-
Extension 2
-
Explanation
The NC basic cycle which is generated on the NC and transferred to the drive via the
drive bus cable has supplied a pulse which does not match the clock timing.
Possible causes: EMC interference on drive bus, NC hardware error, hardware error on
the control module.
Remedy
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the NC hardware, replace the control module.
4-858
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition