Siemens SINUMERIK 840Di Diagnostic Manual page 779

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
301718
Axis %1 drive %2 combination of motor/power section invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The motor cannot be operated with the power section selected.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Check selection of power section.
- Check motor selection.
- Use valid power section.
Program
Switch control OFF - ON.
Continuation:
301719
Axis %1 drive %2 power section data incomplete
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The data for the power section are incomplete:
- Operation of a power section with an FDD motor requires: MD 1178
$MD_INVERTER_DERATING_SYN (derating factor at 8kHz)
- Operation of a power section with an MSD motor requires: MD 1179
$MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- Operation of a power section with a PE MSD motor requires: MD 1179
$MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- MD 1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD)
- MD 1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Carry out new start-up with power section selection or enter the following data:
- Operation of a power section with an FDD motor requires:
- MD 1178 $MD_INVERTER_DERATING_SYN (derating factor at 8kHz)
- Operation of a power section with an MSD motor requires:
- MD 1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- Operation of a power section with a PE MSD motor requires:
- MD 1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)
- MD 1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD)
- MD 1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD).
Program
Switch control OFF - ON.
Continuation: