Siemens SINUMERIK 840Di Diagnostic Manual page 441

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
26228
Channel %1 block %2: The protection area element %3, referred to in
$NP_1ST_PROT[%4], was not found
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of next protection area element
%4 = Index of protection area
Definitions:
The protection area element indicated first in a protection area was not found.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Indicate in $NP_1ST_PROT[...] the name of an existing protection area element.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
26230
Channel %1 block %2: Protection area element %3, referred to in
$NP_NEXT[%4], was not found
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of next protection area element
%4 = Index of protection area
Definitions:
The protection area element indicated next in a protection area was not found.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Indicate in $NP_NEXT[...] the name of an existing protection area element.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
26232
Channel %1 bock %2: Maximum number of %3 protection area elements
exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of next protection area element
Definitions:
The maximum number of permitted protection area elements is too large.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce number of protection areas or protection area elements.
Program
Clear alarm with NC START or RESET key and continue the program.