Siemens SINUMERIK 840Di Diagnostic Manual page 560

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61610
Channel %1 Block %2: No infeed depth programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE76, CYCLE77, CYCLE96.
Remedy:
Check parameter MID.
61611
Channel %1 Block %2: No point of intersection found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No intersection could be calculated with the contour. Alarm triggered by following cycle: CYCLE95.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check contour programming or modify infeed depth.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61612
Channel %1 block %2: Thread finishing not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE97, CYCLE98.
Remedy:
Check the conditions for thread finishing.
61613
Channel %1 block %2: Undercut position incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE94, CYCLE96.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check value in parameter _VARI.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61701
Channel %1 block %2: Error in finished part contour description
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Either none of parameters _NP1, _NP2 and _NP3 supplied or error in finished part contour
programming.
Alarm triggered by following cycle: CYCLE950
Remedy:
- Check parameters _NP1, _NP2 and _NP3.
- Check finished-part contour programming.
61702
Channel %1 block %2: Error in blank contour description
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Either none of parameters _NP5, _NP6 and _NP7 supplied or error in blank contour programming.
The alarm is triggered by the following cycles: CYCLE950
Remedy:
- Check parameters _NP5, _NP6 and _NP7.
- Check blank contour programming.
2-560
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition