Siemens SINUMERIK 840Di Diagnostic Manual page 532

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61277
Channel %1 block %2: Tool diameter larger than restriction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Tool diameter larger than delimitation.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a smaller tool.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61278
Channel %1 block %2: If tool angle is larger than 90°, both tool diameters
must be equal
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For tool angles larger than 90°, the two tool diameters must be identical.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the tool angle or the tool diameters.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61279
Channel %1 block %2: If tool angle equals 90°, both tool diameters must
be equal
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For tool angles equal to 90°, the two tool diameters must be identical.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the tool angle or the tool diameters.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61280
Channel %1 Block %2: Mirroring in WO %4 missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If the program starts with a counterspindle movement, a work offset with mirroring will have to be
selected.
Alarm triggered by following cycle: F_SUB_SP
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select the mirroring for the work offset used.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-532
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition