Siemens SINUMERIK 840Di Diagnostic Manual page 668

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
HMI alarms
112542
GUD variable does not exist or%narray dimension too small:%1
Definitions:
The required GUD variable was not found on read or write access.
Reaction:
Alarm display.
Remedy:
Load the correct GUD variable.
Program
Internal
Continuation:
112543
Prog. was created with higher software version
Definitions:
The part program has been created with a software version higher than the existing one.
Reaction:
Alarm display.
Remedy:
Delete the machining step and reprogram machining if required.
Program
Clear alarm with the Delete key or NC START.
Continuation:
112544
Program cannot be opened.%nIt is already being edited.
Definitions:
Program is already open in HMI Advanced (Program or Services operating area).
Reaction:
Alarm display.
Remedy:
Close program in HMI Advanced (Program or Services operating area).
Program
Clear alarm with the Delete key or NC START.
Continuation:
112546
Program cannot be opened.%nNo read access to the file.
Definitions:
The file has no write access for the current access level.
Reaction:
Alarm display.
Remedy:
Set read access with keyswitch or via password.
Program
Internal
Continuation:
112550
Sequencer programming is not opened.
Definitions:
Option 'Sequencer programming' has not been set.
Reaction:
Alarm display.
Remedy:
The program is opened as G code.
Program
Internal
Continuation:
112560
USB device no longer available,%nexecution from external source no
longer possible.
Definitions:
--
Reaction:
Alarm display.
Remedy:
--
112561
USB device no longer available,%nexecution of Extcall no longer
possible.
Definitions:
--
Reaction:
Alarm display.
Remedy:
--
2-668