RCTR: incorrect MD configuration, channel %1, error in MD: %2
Parameters:
%1 = Channel number
%2 = MD name
Definitions:
The following error was detected in the handling transformation machine data:
TRAFO6_IRORO: The orientation entered in MD TRAFO6_TIRORO_RPY is impermissible.
TRAFO6_TFLWP: The orientation entered in MD TRAFO6_TFLWP_RPY is impermissible.
TRAFO6_TX3P3: The orientation entered in MD TRAFO6_TX3P3_RPY is impermissible.
TRAFO6_MAIN_LENGTH_AB: The value entered in MD TRAFO6_MAIN_LENGTH_AB is incorrect.)
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Alarm display.
Remedy:
Correct machine data
Program
Switch control OFF - ON.
Continuation:
75210
RCTR: Channel: %1, number of axes/axis assignment inconsistent
Parameters:
%1 = Channel number
Definitions:
On transformation selection an incorrect axis assignment is detected:
The axes entered in MD TRAFO_AXES_IN_1 do not match MD TRAFO6_NUM_AXES.
Reaction:
Interpreter stop
Alarm display.
Remedy:
Correct machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75212
RCTR: channel %1, incorrect TRAFO_TYPE_ : use 4100
Parameters:
%1 = Channel number
Definitions:
The transformer type entered in MD TRAFO_TYPE_x is incorrect
Reaction:
Interpreter stop
Alarm display.
Remedy:
TRAFO_TYPE 4100 is to be used
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75250
RCTR: channel %1, tool parameters incorrect interpreter
Parameters:
%1 = Channel number
Definitions:
On block interpretation incorrect tool parameters are detected:
Reaction:
Interpreter stop
Alarm display.
Remedy:
Correct tool parameters.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75255
RCTR: channel: %1, unreachable position interpreter
Parameters:
%1 = Channel number
Definitions:
On block interpretation a non-approachable position is detected:
Reaction:
Interpreter stop
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation: