10203
Channel %1 NC start without reference point (action=%2<ALNX>)
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
NC start has been activated in the MDI or AUTOMATIC mode and at least one axis that needs to be
referenced has not reached its reference point.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Via the channel-specific MD 20700:
REFP_NC_START_LOCK (NC Start without reference point) you can decide whether the axis must
be referenced before NC Start or not. The start of referencing can be enabled channel-specific or axis-
specific.
Channel-specific reference point approach: The rising edge of the interface signal "activate
referencing" (DB 21 - 28, DBX 1.0) starts an automatic sequence which starts the axes of the channel
in the same sequence as specified in the axis-specific MD 34110 REFP_CYCLE_NR (axis sequence
channel-specific referencing). 0: The axis does not participate in channel-specific referencing, but it
must be referenced for NC Start, -1: The axis does not participate in channel-specific referencing, but
it need not be referenced for NC Start, 1- 8: Starting sequence for the channel-specific referencing
(simultaneous start at the same no.), 1 - 31: CPU type
Axis-specific referencing: Press the direction key that corresponds to the approach direction in the
axis-specific MD 34010 REFP_CAM_MDIR_IS_MINUS (reference point approach in minus direction).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10204
[up to SW 3.x only] Channel %1 general error
Parameters:
%1 = Channel number
Definitions:
A general error has occurred in the channel.
Reaction:
Alarm display.
Remedy:
This message indicates an internal conflict with no further consequences.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10205
[up to SW 3.x only] Channel %1 internal error in %2
Parameters:
%1 = Channel number
%2 = String
Definitions:
An internal error has occurred in the channel.
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Press RESET.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10206
[up to SW 3.x only] Channel %1 general error in function generator
Parameters:
%1 = Channel number
Definitions:
An error has occurred during activation/deactivation of the function generator.
Reaction:
Alarm display.
Remedy:
Press RESET.
Program
Clear alarm with the Delete key or NC START.