Overview of Alarms
NCK alarms
22322
Channel %1 axis %2 PRESET: illegal value
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The entered Preset value is too large (number format overflow).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use more realistic (smaller) Preset values.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
22400
Channel %1 option 'contour handwheel' not set
Parameters:
%1 = Channel number
Definitions:
The function 'contour handwheel' was activated without the neccesary option.
If the alarm occurs
- on selection of the contour handwheel via the PLC, then the contour handwheel has to be deselected
in order to continue with the program
- on account of programming FD=0, then the program can be corrected and continued with the
compensation block and NCSTART.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Set option
- Cancel the activation of the function 'contour handwheel'
- Modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
25000
Axis %1 hardware fault of active encoder
Parameters:
%1 = Axis name, spindle number
Definitions:
The signals of the currently active position actual value encoder (interface signal DB 31 - 48, DBX 1.5
= 1 or DBX 1.6 = 1) are missing, do not have the same phase, or exhibit grounding/short-circuit.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not
ready).
Reaction:
Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Axes of this channel must be re-referenced.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
Please inform the authorized personnel/service department. Check measuring circuit connectors for
correct contacting. Check encoder signals and replace the encoder if faults are found.
Program
Switch control OFF - ON.
Continuation: