11/2006
61204
Channel %1 block %2: Technology cycle unknown
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified technology cycle in the machining block is unknown.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete and reprogram the technology block.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61205
Channel %1 block %2: Position cycle unknown
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified positioning cycle in the machining block is unknown.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete and reprogram the positioning block.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61210
Channel %1 block %2: Block search element not found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The element specified for the block search does not exisit.
Alarm triggered by following cycles: E_MANAGE, E_PS_CIR, E_PS_MRX, E_PS_POL, E_PS_SEQ,
E_PS_XYA, F_MANAGE, F_PS_CIR, F_PS_MRX, F_PS_SEQ
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Repeat block search.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61211
Channel %1 block %2: Absolute reference missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An incremental indication was made, but the absolute reference is unknown.
Alarm triggered by following cycles: E_MI_CON, E_MI_PL, E_PI_CIR, E_PI_REC, E_PO_CIR,
E_PO_REC, E_PS_CIR, E_PS_HIN, E_PS_MRX, E_PS_POL, E_PS_SEQ, E_PS_XYA, E_SL_CIR,
E_SL_LON, F_PS_CIR, F_PS_MRX, F_PS_SEQ
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program an absolute position prior to using incremental indications.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms