1. FUNCTIONS AND CONFIGURATION
MR-J2S- -S084
Item
Dog type
Count type
Data setting type
Stopper type
Manual
Home position
home
ignorance
position
(Servo-on position as
return
home position)
mode
Dog type rear end
reference
Count type front end
reference
Dog cradle type
Automatic positioning to home
position
Other functions
Structure
Operation
Ambient
temperature
Storage
Operation
Ambient
humidity
Storage
Ambient
Altitude
Vibration
Weight
Servo amplifier
10CP
20CP
Home position return is made starting with Z-phase pulse after passage of proximity dog.
Home position address may be set. Home position shift distance may be set. Home position
return direction may be selected.
Automatic at-dog home position return return/automatic stroke return function
Home position return is made by counting encoder pulses after contact with proximity dog.
Home position address may be set. Home position shift value may be set. Home position
return direction may be set.
Automatic at-dog home position return return/automatic stroke return function
Home position return is made without dog.
Home position may be set at any position by manual operation, etc. Home position address
may be set.
Home position return is made by pressing machine part against stroke end.
Home position address may be set. Home position return direction may be set.
Position where servo-on (RYn0) is switched on is defined as home position.
Home position address may be set.
Home position return is made with respect to the rear end of a proximity dog.
Home position address may be set. Home position shift value may be set. Home position
return direction may be set.
Automatic at-dog home position return return/automatic stroke return function
Home position return is made with respect to the front end of a proximity dog.
Home position address may be set. Home position shift value may be set. Home position
return direction may be set.
Automatic at-dog home position return return/automatic stroke return function
Home position return is made with respect to the front end of a proximity dog by the first
Z-phase pulse.
Home position address may be set. Home position shift value may be set. Home position
return direction may be set.
Automatic at-dog home position return return/automatic stroke return function
High-speed automatic return to a defined home position.
Absolute position detection, backlash function
Overtravel prevention using external limit switch
Software stroke limit
Self-cooled, open (IP00)
[ ] 0 to 55 (non-freezing)
[ ] 32 to 131 (non-freezing)
[ ]
20 to 65 (non-freezing)
[ ]
4 to 149 (non-freezing)
90%RH or less (non-condensing)
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Max. 1000m (3280ft) above sea level
5.9 [m/s
2
] or less
19.4 [ft/s
2
] or less
[kg]
0.7
0.7
[lb]
1.5
1.5
40CP
60CP
70CP 100CP 200CP 350CP 500CP 700CP 10CP1 20CP1 40CP1
Force-cooling, open (IP00)
1.1
1.1
1.7
1.7
2.4
2.4
3.75
3.75
1 - 8
2.0
2.0
4.9
7.2
4.4
4.4
10.8 15.87
Self-cooled,
open (IP00)
0.7
0.7
1.1
1.5
1.5
2.4

Hide quick links: