3. CC-Link COMMUNICATION FUNCTIONS
(2) Write instruction codes (80000 to 911FH)
Instruction code
(RWwn+2)
Writing data
(RWwn+3)
Instruction code
execution demand
(RYn9)
Instruction code
processing
Instruction code
execution completion
(RXn9)
Answer code
(RWrn+2)
Set the write instruction code (refer to Section 3.5.4 (2)) to Instruction code (RWwn+2) and the data to
be written (data to be executed) to Writing data (RWwn+3) in hexadecimal, and turn Instruction code
execution demand (RYn9) to ON.
Turning instruction code execution completion to ON sets the data set in Wiring data (RWwn+3) to
the item corresponding to the write instruction code. When write is executed, Instruction code
execution completion (RXn9) turns to ON.
If the instruction code not in the specifications is set to Instruction code (RWwn+2), the corresponding
error code (
1 ) is set to Answer code.
Turn Instruction code execution demand (RYn9) to OFF after Instruction code execution completion
(RXn9) has turned to ON.
Write in execution
3 - 37