1. FUNCTIONS AND CONFIGURATION
(4) MR-J2S-700CP-S084
MODE
UP
DOWN
Cooling fan
Installation notch
(4 places)
POINT
The servo amplifier is shown without the front cover. For removal of the
front cover, refer to Section 1.6.3.
Battery connector (CON1)
Used to connect the battery for absolute position data
backup.
Battery holder
Contains the battery for absolute position data backup.
Display
The 5-digit, seven-segment LED shows the servo
status and alarm number.
Operation section
Used to perform status display, diagnostic, alarm,
SET
parameter and point table setting operations.
I/O signal connector (CN1A)
Used to connect digital I/O signals.
I/O signal connector (CN1B)
Used to connect digital I/O signals.
MR-J2S-T01 connector (CN3)
Connector for connection of the MR-J2S-T01 CC-Link
option unit.
Charge lamp
Lit to indicate that the main circuit is charged.
While this lamp is lit, do not reconnect the cables.
Control circuit terminal block (TE2)
Used to connect the control circuit power supply.
Encoder connector (CN2)
Connector for connection of the servo motor encoder.
Name plate
Main circuit terminal block (TE1)
Used to connect the input power supply, regenerative
brake option and servo motor.
Name/Application
MODE
UP
DOWN
Protective earth (PE) terminal (
Ground terminal.
1 - 17
SET
Used to set data.
Used to change the
display or data in each
mode.
Used to change the
mode.
)
Reference
Section5.5
Section5.5
Chapter8
Chapter8
Section4.3
Section4.3
Chapter7
Section15.1.4
Section4.7
Section13.1
Section4.3
Section15.1.4
Section1.4
Section4.7
Section13.1
Section15.1.1
Section4.10
Section13.1