Mitsubishi Electric MELSERVO-J2-Super Series Instruction Manual page 66

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

3. CC-Link COMMUNICATION FUNCTIONS
Signal name
Reset
Forced stop
Note 1. Can be used as a CN1A/CN1B external input signal by setting parameter No. 116 to 118, parameter No. 79 to 83.
2. Can be automatically turned ON (kept ON) internally by setting parameter No. 84 to 86.
Description
Keeping RY(n+1)A or RY(n+3)A ON for 50ms or longer
allows an alarm to be deactivated.
Some alarms cannot be deactivated by Reset RY(n+1)A or
RY(n+3)A. (Refer to Section 11.2.1.)
If RY(n+1)A or RY(n+3)A is turned ON with no alarm
occurring, the base circuit is shut off. When " 1
in parameter No. 55 (function selection 6), the base circuit
will not be shut off.
This signal is not designed to make a stop. Do not turn it
ON during operation.
This signal is exclusively used as a CN1A/CN1B external
input signal.
It cannot be used for CC-Link.
Opening EMG-SG results in a forced stop status, switches
the servo off, and operates the dynamic brake to make a
sudden stop.
Short EMG-SG in the forced stop status to cancel the
forced stop status.
" is set
3 - 17
Device No.
Remarks
1 station
2 stations
occupied
occupied
RY(n+1)A
RY(n+3)A
(Note 1)