Brother HL-2600CN Service Manual page 98

Color laser printer
Hide thumbs Also See for HL-2600CN:
Table of Contents

Advertisement

The COMMAND signal and STATUS signal are the signals that are used to
transfer the data between the controller and the engine, which perform as a
half-duplex asynchronous serial communication. Refer to Fig.4-40.
6WDUW ELW
LSB
Note:
x
Based on "Asynchronous Communication" method.
x
Command/Status communication must keep the "Handshake Rule".
x
Baud rate is 9600 bps.
x
Frame format: - one (1) start bit,
- eight (8) data bits
(Start bit side is LSB, Parity bit is MSB),
- one (1) odd parity bit,
- one (1) stop bit.
x
The video controller has to send an "Initialize Command" to the engine controller
after power on in order to establish communication.
The power for the Main PCB is supplied through the engine interface
connector.
6WRS ELW
3DULW\ ELW
P
8ms (TYP)
MSB
LSB
6WDUW ELW
Fig.4-39
IV-47
30ms (MAX)
MSB
P
3DULW\ ELW
6WRS ELW