4.7 Detailed Functions in CONFIGURATION Mode

Item
I.SETT: (CANCEL /
SET)
Initial Setting
SAVE: (CANCEL /
SAVE)
SAVE
TEACH: (OK / OK NG)
Teaching
B.L.PTN:
(ON/OFF10/OFF30/O
FF60)
Backlight Pattern
L.ON.OF: (ON / OFF)
LED On / Off
A.SAVE: (ON / OFF)
Auto Save
ST.NO: (1 ~ 99)
Station Number
BAUD.R: (9.6 ~ 57.6
kbps)
Baud Rate
OUT.D: (0 ~ 160 ms)
20 ms
Output Delay
Description
Returns to the default settings for each item in CONFIGURATION (refer
to the section describing CONGIFURATION mode for each application)
section 4, "Inspection Applications" for more information on
Saves the current configuration data
To save the current configuration data:
Select "SAVE" and press the TRIGGER button for three seconds. Once
the data are saved, "DONE" appears on the operation unit.
Automatically input the allowable range according to the difference of the
detection value after executing a teaching for OK product and NG
product. OK: Executes a teaching for base OK product
OK NG: Execute a teaching for NG product after executing a teaching
for OK product. The allowable range is set to around the median
between the detection values for OK product and NG product. You can
change it in JDGEMENT CRITERIA SETTING mode.
Turns the backlight on the finder unit off at a certain time after operating
the operation unit. The longer the backlight off time, the longer the
expected service life of the backlight. Turn it on only when needed.
ON: Always turns off. Never turns on.
OFF10: Turns off after 10 minutes
OFF30: Turns off after 30 minutes
OFF60: Turns off after 60 minutes
Allows you to select whether or not to use a built-in LED light.
ON: The built-in LED emits per inspection execution
OFF:
The built-in LED does not emit. Please separately install lighting
equipment for image processing.
Automatically saves setting or changed data when the mode was
changed from JUDGEMENT CRITERIA SETTING mode to
INSPECTION mode or from TEACHING mode to INSPECTION mode
ON: Activate the Auto Save function
OFF: Cancel the Auto Save function (Save the setting or changed
data manually before turning the unit off.)
Indicates the unit (station) number used for serial communication. If you
want to connect multiple LightPix units through the
RS-232C-to-RS485/RS485-toRS232C conversion adapter a conversion
adapter, allocate different station numbers to each unit.
Allows you to select communication speed for RS-232C communication.
Set the same communication speed as the destination unit.
Selectable communication speeds: 9.6 / 14.4 / 19.2 / 38.4 / 57.6 (kbps)
Waits the setting time after the original timing and outputs inspection
results. After that, the READY signal is turned on, and the inspection
time (READY signal OFF time) becomes longer by the set output delay
time.
Applica-
tion
All
All
All
All
All
All
All
All
All
95