Panasonic LightPix AE20 User Manual page 60

Table of Contents

Advertisement

Operation in TEACHING mode
Operation in TEACHING mode differ the type of teaching. (The type of teaching is
settable in CONFIGURATION mode.)
The number in < > in the table below represents the button number of the operation
unit (see the figure on the right).
TEACH: OK (teaching for OK product only)
In INSPECTION (or RUN)
mode
In TEACHING mode ("TEACH" is displayed)
TEMP: Saved template
The saved template image is
displayed at the left upper
area on the finder unit.
Exposure time: 0.03 ~ 50.00 ms (default:
1.93)
<7> : Shortens the exposure time
<8> Extends the exposure time
If you want to perform a teaching at this point,
press <6> and then <1>
SIZE: Resizes inspection area
If you want to perform a teaching at this point,
press <6> and then <1>.
MOVE: Moves the inspection area
you want to execute a teaching, press <6> and
then <1>.
T.SIZE: Resizes the Color Extraction area
If you want to execute teaching, press <6> and
then <1>.
T.MOVE: Moves the Color Extraction area
If you want to execute a teaching at this point,
press <6> first and then <1> after resizing.
M.SIZE: Resizes the template area
If you want to perform a teaching at this point,
press <6> and then <1>.
M.MOVE: Moves template area
If you want to perform a teaching at this point,
press <6> and then <1>.
The <6> button: Executes a teaching
Teaching is performed for OK products of the
current product type.
ADJ: Teaching is being performed
Values (two digits): The degree of similarity
detected during the test run
When the unit completed a teaching, the
degree of similarity appears in the ADJ display
area.
<5>: Returns to the top.
NO TEMP:
When no
template is
saved
Product
switch
Press <2> and
<5> at the same
time to change
the product
types.
Display of
teaching
completion
Execute a
teaching If
teaching is
successfully
completed by
the time of
inspection area
move, "DONE"
is displayed a
the upper line
Example:
53

Advertisement

Table of Contents
loading

Table of Contents