ST.NO: (1 ~ 99)
Station Number
Station Number function:
Sets a device number (unit) used
for RS-232C communication
BAUD.R: (9.6 ~ 57.6 kbps)
Baud Rate function:
Sets RS-232C communication
speed
OUT.D: (0 ~ 160 ms) 20 ms
Output Delay function:
Outputs inspection results after the
original output timing
CAP.D: (0 ~ 160 ms) 1 ms
Capture Delay function:
Sets the time delay from TRIGGER
signal input to image capture
I.TRR: (ON / OFF)
Internal Trigger function:
When the function is set to ON, the
LightPixAE20 automatically
performs continuous inspections.
When OFF, it performs an
inspection every time trigger signal
input.
INI.T: (1 ~ 7)
Initial Type:
The selected product type number
when the LightPixAE20 is turned on
(available only for colored areas)
VER
Version:
Version, size of view range and
system and operation unit versions
(size of view range differs
depending on the product number.)
T.TRG: (ON / OFF)
Teaching Trigger function:
Sets external trigger to ON (valid) or
OFF (invalid)
A.BACK: (ON / OFF)
Answer Back function:
Displays a detected color in blue on
the finder unit