Setting Up The Judgement Criteria In Judgement Criteria Setting Mode - Panasonic LightPix AE20 User Manual

Table of Contents

Advertisement

4.5.5 Setting Up the Judgement Criteria in JUDGEMENT CRITERIA SETTING
Mode
Based on the base distance in the X and Y directions between the left upper of the point in the inspection area
and the detected point saved by teaching, set the limit for OK judgement in mm. When executing a teaching,
the proper values for teaching type and for detected distance between the left upper of the point in the
inspection area and the detected point are set. Change the allowable limit in JUDGEMENT CRITERIA
SETTING mode as necessary.
Operation in JUDGEMENT CRITERIA SETTING
The number in < > in the table below represents the button number of the
operation unit (see the figure on the right).
In INSPECTION (or RUN)
mode
In JUDGEMENT CRITERIA SETTING mode ("SET" is displayed.)
Ref X: Base peak distance – X direction
Peak distance saved by teaching: The value of
X-directional distance
Ref Y: : Base peak distance- Y direction
Peak distance saved by teaching: The value of
Y-directional distance
Per X: Allowable range-in the X direction
<8>: Increases the value (= extends the allowable range)
<7>: Decreases the value (= reduces the allowable range)
Per Y: Allowable range – Y direction
Setting of allowable range in the Y direction
<8>: Increases the value (= extends the allowable range)
<7>: Decreases the value (= reduces the allowable range)
To product
type No.2
79

Advertisement

Table of Contents